How it differs from the standard method

  • Needs a matched antibody pair.
  • Biotin–streptavidin detection amplifies the signal; avoid milk as a blocker (it contains biotin).

1How an ELISA turns binding into colour

An enzyme-linked immunosorbent assay captures the molecule you want on the bottom of a plastic well and labels it with an enzyme, usually horseradish peroxidase (HRP). After each step, unbound material is washed away.

1–5 µg/mL, overnight

Coat

Capture antibody (or antigen) sticks to the polystyrene by passive adsorption.

1 h

Block

A protein such as BSA covers the remaining plastic so later reagents can't stick to it.

1–2 h

Bind and detect

Sample, then a labelled detection antibody, with washes between every step.

10–20 min

Develop and read

TMB colour develops in the dark; stop with acid and read OD 450.

2Four formats

Direct
Antigen on the plate, detected by one enzyme-labelled antibody. Quick, but less sensitive.
Indirect
Antigen on the plate, an unlabelled primary antibody, then an enzyme-labelled secondary. Used to measure antibodies in serum (titres).
Sandwich
Capture antibody on the plate binds the analyte; a second antibody to a different epitope detects it. The most specific and sensitive format for proteins in complex samples.
Competitive
Sample analyte competes with labelled analyte for limited antibody, so signal falls as concentration rises. Used for small molecules (hormones, drugs) that can't bind two antibodies.

3From OD to concentration

Every plate carries a serial dilution of a known standard. OD against log concentration gives an S-shaped curve, usually fitted with a four-parameter logistic (4PL).

Standard curve

Signal for a dilution series of known concentrations, used to convert sample signal into concentration.

4PL fit

Four-parameter logistic: bottom, top, midpoint (EC50) and slope. The usual model for ELISA curves.

Blank

Wells with every reagent but no analyte. They measure background, which is subtracted.

LLOQ / ULOQ

Lower and upper limits of quantification: the concentration range where the curve gives accurate values.

Matrix effect

Interference from other components of the sample (serum proteins, lipids) that changes the signal.

Hook effect

In one-step sandwich assays, extremely high analyte saturates both antibodies separately and paradoxically lowers the signal.

When to use it

  • Measuring the concentration of one protein (cytokine, hormone, biomarker) in serum, plasma or culture supernatant.
  • Screening many samples in parallel on 96- or 384-well plates.
  • Measuring antibody titres after immunisation or infection (indirect format).

Compared with alternatives

Western blot →

Shows the protein's size and is semi-quantitative; ELISA gives concentrations for many samples faster.

Multiplex immunoassays →

Measures dozens of analytes in one small sample; ELISA is simpler, cheaper and well validated for a single analyte.

Protein quantification →

Bradford and BCA measure total protein; ELISA measures one specific protein.

Flow cytometry & FACS →

Measures proteins on or in single cells rather than secreted into fluid.

Sub-techniques

Choosing one here switches the whole page, including the protocol and the lab, to it.

Two antibodies to different epitopes: one captures, one detects. High specificity and sensitivity (pg/mL) in complex samples like serum and supernatants.

  • Needs a matched antibody pair.
  • Biotin–streptavidin detection amplifies the signal; avoid milk as a blocker (it contains biotin).