Cell counting & viability
Manual counting in a ruled chamber under a 10× objective. Cheap and transparent, but slow and operator-dependent.
Our ruleSimulations prepare you for the bench but don't replace hands-on practice.
Hemocytometer
Manual counting in a ruled chamber under a 10× objective. Cheap and transparent, but slow and operator-dependent.
1Counting cells in a known volume
A hemocytometer is a thick glass slide with a precisely etched grid. When the coverslip sits on its ridges, the chamber is exactly 0.1 mm deep, so each 1 × 1 mm large square holds 0.1 µL (10⁻⁴ mL). Count the cells in several large squares, average them, and multiply by 10⁴ and by any dilution to get cells per mL.
Density
Mean cells per large square × 10⁴ × dilution factor.
Viability
Unstained cells ÷ all cells × 100. Healthy log-phase cultures are usually above 90%.
Precision
Counting is a Poisson process: 100 cells gives ~10% error, 400 cells ~5%.
2Dye exclusion
Trypan blue is a large charged dye that can't cross an intact membrane. Live cells stay bright and refractile; cells whose membranes have failed take it up and look blue. The dye itself is toxic, so live cells begin to stain after a few minutes: count within 3–5 minutes of mixing.
3Where counts go wrong
- Cells settle and clump within minutes: mix gently right before taking the sample.
- Overfilling lifts the coverslip and makes the chamber deeper than 0.1 mm, inflating the count.
- Cells on the grid lines must follow a rule (count top and left, skip bottom and right) or edge cells get counted twice.
- Too many cells per square (over ~100) and you miss some; too few and the count is noisy.
Key terms
Practise these as flashcards →Counting chamber with a ruled grid and fixed depth (Neubauer improved: 0.1 mm).
1 × 1 mm square; at 0.1 mm depth it holds 0.1 µL.
Every dilution applied before counting, including the dye (1:1 trypan blue = ×2).
Percentage of cells with intact membranes (unstained).
Fraction of the dish surface covered by adherent cells; estimated by eye, not counted.
When to use it
- Before every seeding, transfection or freezing step, so each well or vial gets a known number of live cells.
- To follow growth and decide when to passage.
- To check a thawed or treated culture's health.
Compared with alternatives
Plate assays (MTT, CellTiter-Glo) measure viability of whole wells after a treatment rather than counting single cells.
Counts and classifies thousands of cells with viability dyes and markers; overkill for routine counts.
Counting is the step that tells you how to split.
The microbiology equivalent: count colonies from plated dilutions.
Sub-techniques
Choosing one here switches the whole page, including the protocol and the lab, to it.
Manual counting in a ruled chamber under a 10× objective. Cheap and transparent, but slow and operator-dependent.