TEM & SEM

Particles adsorbed to a glow-discharged carbon film are embedded in a thin layer of heavy-metal stain, which outlines their shape at about 2 nm resolution. Fast, cheap and the standard check of sample quality.

nm scaleSimulator readyCore simulatorEngine: Microscopy & imaging
Choose a sub-technique

Our ruleSimulations prepare you for the bench but don't replace hands-on practice.

Sub-technique you chose

Negative staining

Particles adsorbed to a glow-discharged carbon film are embedded in a thin layer of heavy-metal stain, which outlines their shape at about 2 nm resolution. Fast, cheap and the standard check of sample quality.

How it differs from the standard method

  • Dilute until particles rarely touch; avoid phosphate buffers with uranyl stains.
  • Blot to leave stain about as deep as the particles.
  • Uranyl acetate or formate for contrast; methylamine tungstate or other non-uranium stains are alternatives.

1Imaging with electrons

Electrons accelerated through tens of kilovolts have wavelengths of a few picometres, so electron microscopes resolve detail a hundred times finer than light can. In transmission electron microscopy (TEM) a broad beam passes through a specimen thin enough for electrons to cross it (sections of 50–100 nm, or particles on a carbon film) and the image is formed by the electrons that are not scattered away.

vacuum

Dry and fixed

The column is under high vacuum, so specimens must be fixed and either dried, embedded in resin, or frozen. Every step of that preparation can create artefacts that look like structure.

contrast

Heavy metals

Negative stain outlines particles in a glass of uranyl acetate; positive stains bind membranes and nucleic acids; colloidal gold marks antibodies as dense black dots of a chosen size.

SEM

Surface and charge

Non-conductive samples charge under the beam unless coated with a few nanometres of metal or imaged at low voltage; higher voltages penetrate deeper and blur surface detail.

dose

Beam damage

Electrons break bonds. Minimal-dose imaging and cryo methods protect delicate specimens; negative stain and resin are more forgiving.

2Negative staining

The quickest way to look at purified particles, viruses, filaments or large complexes. A drop of sample is adsorbed to a carbon film made hydrophilic by glow discharge, washed with water, then covered with a heavy-metal salt such as 2% uranyl acetate, blotted and dried.

3Immunogold and correlative imaging

To localise a protein at nanometre resolution, ultrathin sections are labelled with a primary antibody and then protein A or a secondary antibody coupled to colloidal gold of 5–15 nm. Thawed cryosections (Tokuyasu method) of lightly fixed cells preserve antigenicity best; strong glutaraldehyde fixation and resin embedding preserve morphology but mask epitopes.

Negative stain

A heavy-metal salt that dries around particles so they show as light shapes on a dark background.

Glow discharge

A brief plasma treatment that makes carbon films hydrophilic so samples and stain spread evenly.

Tokuyasu cryosection

An ultrathin section cut from a sucrose-infused, frozen, lightly fixed sample, labelled after thawing.

Colloidal gold

Gold nanoparticles of defined size coupled to protein A or antibodies, visible as dense dots in TEM.

Labelling density

Gold particles per µm² of a compartment, compared between compartments and with controls.

Critical-point drying

Removing liquid CO₂ above its critical point so no liquid–gas interface crosses the specimen and its surface tension cannot collapse it.

Sputter coating

Depositing a few nanometres of metal on an SEM specimen to make it conductive.

CLEM

Correlative light and electron microscopy: imaging the same cell or structure by fluorescence and by EM.

When to use it

  • Checking the shape, size and homogeneity of purified particles or complexes quickly: negative-stain TEM.
  • Locating a protein relative to membranes and organelles below the light microscope's resolution: immunogold TEM.
  • Imaging cell and tissue surfaces, microvilli, cilia or biomaterial interfaces: SEM; finding rare events first by fluorescence: CLEM.

Compared with alternatives

Cryo-EM →

Images particles frozen in vitreous ice without stain for near-atomic structures; negative stain is the quick screen before it.

Super-resolution →

Reaches tens of nanometres with fluorescence in hydrated, even living, cells, without metal stains.

Immunofluorescence →

Localises proteins in whole cells quickly at light-microscope resolution; the usual first step before immunogold.

Dynamic light scattering →

Measures particle size distributions in solution in minutes, without seeing individual particles.

Sub-techniques

Choosing one here switches the whole page, including the protocol and the lab, to it.

Particles adsorbed to a glow-discharged carbon film are embedded in a thin layer of heavy-metal stain, which outlines their shape at about 2 nm resolution. Fast, cheap and the standard check of sample quality.

  • Dilute until particles rarely touch; avoid phosphate buffers with uranyl stains.
  • Blot to leave stain about as deep as the particles.
  • Uranyl acetate or formate for contrast; methylamine tungstate or other non-uranium stains are alternatives.